Initial Configuration 37
© 2012 Datacom Systems Inc
4.1.4.18 SET TCP PORT (SE TC PO)
This command configures the TCP Port (default 2370) parameter. Initially this should be done using
the serial port with a terminal application. The parameter is entered as shown:
SET TCP PORT (SE TC PO) [nnnnn]
Example:
# SE TC PO 17216
TCP Port is now updated.
#
4.1.4.19 SET UPGRADE (SE UP)
This command sets the FLASHutils service (default ENABLED) process. It is entered as shown:
SET UPDATE (SE UP) [OFF or ON]
Example 1:
# SE UP OFF
The FlashUtils protocol is now disabled.
#
Example 2:
# SE UP ON
The FlashUtils protocol is now enabled.
#
4.1.4.20 SET TELNET (SE TT)
This command sets the TELNET service (default ENABLED) process. It is entered as shown:
SET TELNET (SE TT) [OFF or ON]
Example 1:
# SE TT OFF
The Telnet protocol will be disabled at end of session.
#
Example 2:
# SE TT ON
The Telnet protocol will be enabled at end of session.
#