Datacom Systems SS series SPAN Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Mise en réseau Datacom Systems SS series SPAN. Datacom Systems SS series SPAN User guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 110
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
© 2012 Datacom Systems Inc
SS-1200-S, SS-2200-S, SS-4200-S Series
Link Aggregation Taps
Datacom Systems Inc
Access Your Network
TM
June 2012
541-0132-U-B.02
USER
guide
SS-1200-S Series Link Aggregation Taps
SS-2200-S Series Dual-Link Aggregation Taps
SS-4200-S Series Quad-Link Aggregation Taps
Vue de la page 0
1 2 3 4 5 6 ... 109 110

Résumé du contenu

Page 1 - Datacom Systems Inc

© 2012 Datacom Systems IncSS-1200-S, SS-2200-S, SS-4200-S SeriesLink Aggregation TapsDatacom Systems IncAccess Your NetworkTMJune 2012541-0132-U-B.02U

Page 2

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps10© 2012 Datacom Systems Inc1.5 Certifications and MarksCAUTION: Changes or modificatio

Page 3 - Product Description

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps100© 2012 Datacom Systems Inc6. AcknowledgmentsThe production and maintenance of this m

Page 4

Appendix B - Power Supply MIB 101© 2012 Datacom Systems Inc[DSI-SMI] Datacom Systems, Inc., "The Datacom Structure of Management Information(SMI)

Page 6

Appendix C - Structure of Management Information MIB 103© 2012 Datacom Systems Inc11 Appendix C - Structure of Management Information MIBThe Datacom S

Page 7

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps104© 2012 Datacom Systems Inc and administrative registrations within the Datacom pri

Page 8

Appendix C - Structure of Management Information MIB 105© 2012 Datacom Systems Inc module. agentCaps(2) The agentCaps subtree prov

Page 9 - 1 Terms of Use

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps106© 2012 Datacom Systems Inc Copyright (C) 2010 Datacom Systems Inc. All rig

Page 10 - 1.5 Certifications and Marks

Appendix C - Structure of Management Information MIB 107© 2012 Datacom Systems Inc Definitions occur within the DATACOM-AGENT-CAPS MIB

Page 11 - 2 Overview

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps108© 2012 Datacom Systems Inc8.1 Normative References [RFC2119] Bradner, S., "Ke

Page 12 - 2.3 What Shipped?

Appendix D - FLASHutils 109© 2012 Datacom Systems Inc12 Appendix D - FLASHutilsA small utility to update firmware from a binary file.1. Insert the CD

Page 13 - Overview 13

Overview 11© 2012 Datacom Systems Inc2 OverviewThe SINGLEstream family of products increases network visibility and leverages your investmentin netwo

Page 14

Datacom Systems Inc.9 Adler Drive • East Syracuse, NY 13057TEL: (315) 463-9541 • FAX: (315) 463-9557http://www.datacomsystems.comDatacom Systems IncAc

Page 15 - Overview 15

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps12© 2012 Datacom Systems Inc2.3 What Shipped?SS-1200-S Series Link Aggregation Taps1 —

Page 16

Overview 13© 2012 Datacom Systems IncInstalled Management RJ45 port and Serial DB9 port allow for complete configurationthrough a simple, easy to use

Page 17 - 3 Hardware

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps14© 2012 Datacom Systems Inc2.6 SS-1200 Series Model Specific SpecificationsSS-1204BT-B

Page 18 - SS-4210BT-SFP-S

Overview 15© 2012 Datacom Systems Inc2.8 SS-4200 Series Model Specific SpecificationsSS-4210BT-SFP-S:Tap Connections: 4 - 10/100/1000BaseT In-Line (R

Page 20

Hardware 17© 2012 Datacom Systems Inc3 HardwareFront panel images of the SS-1200-S, the SS-2200-S and the SS-4200-S series are provided inthis section

Page 21 - 3.5 Rear Panel Description

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps18© 2012 Datacom Systems Inc3.2 SS-2200 Series Front PanelsSS-2206BT-BT-SSS-2206SX-SFP-

Page 22

Hardware 19© 2012 Datacom Systems Inc3.4 Front Panel DescriptionThis section provides a illustration and description of the front panel of the SS-1200

Page 24 - 4.1.3.2 HELP (HE) or (?)

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps20© 2012 Datacom Systems IncLX-BT/SX-BT - TAP (SS-1204LX-BT-S and SX-BT-S port 3 and po

Page 25 - 4.1.3.3 POWER STATUS (PO ST)

Hardware 21© 2012 Datacom Systems IncLX-BT/SX-BT - The LEDs located to the right of the SFP connectors are solid green indicating a linkhas been detec

Page 26 - 4.1.3.4 SHOW (SH)

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps22© 2012 Datacom Systems Inc3.5.1 Serial DB9The SERIAL connector port is a shielded DB9

Page 27 - 4.1.3.5 SHOW GROUPS (SH GR)

Initial Configuration 23© 2012 Datacom Systems Inc4 Initial ConfigurationIMPORTANT: Prior to initial configuration of the hardware, it is imperative t

Page 28

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps24© 2012 Datacom Systems IncBase Prompt: This is the text presented to the user logging

Page 29 - Initial Configuration 29

Initial Configuration 25© 2012 Datacom Systems IncExample: > ?Available commands:ADD USER AD US Add UserDELETE USER DE US Delete UserEDIT USER ED U

Page 30 - 4.1.3.10 SHOW TIME (SH TI)

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps26© 2012 Datacom Systems Inc4.1.3.4 SHOW (SH)Using this command alone, displays general

Page 31 - 4.1.4.3 SET PROMPT (SE PR)

Initial Configuration 27© 2012 Datacom Systems Inc4.1.3.5 SHOW GROUPS (SH GR)This command displays all ports as designated by the administrator (Supe

Page 32 - 4.1.4.7 SET DATE (SE DA)

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps28© 2012 Datacom Systems Inc4.1.3.7 SHOW PORT CONFIG (SH PO CO)This command displays a

Page 33 - 4.1.4.10 SET SUBNET (SE SU)

Initial Configuration 29© 2012 Datacom Systems Inc CFG: Auto Negotiate Current: No Link LinkProtect OFF Type: Tap (6..5)

Page 34 - 4.1.4.11 SET GATEWAY (SE GA)

Product DescriptionDatacom Systems Inc. SINGLEstream™ SS-1200-S Series Link AggregatingTaps, the SS-2200-S Series Dual-Link Aggregating Taps and the S

Page 35 - Initial Configuration 35

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps30© 2012 Datacom Systems Inc4.1.3.8 SHOW PORT ROUTING (SH PO RO)This command displays,

Page 36

Initial Configuration 31© 2012 Datacom Systems Inc4.1.3.11 SHOW USERS (SH US)Displays all users for the configurable product. The response asterisk in

Page 37 - 4.1.4.20 SET TELNET (SE TT)

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps32© 2012 Datacom Systems Inc4.1.4.4 ADD USER (AD US)Add users, it is entered as shown:A

Page 38 - 4.1.4.23 SET PING (SE PI)

Initial Configuration 33© 2012 Datacom Systems Inc4.1.4.8 SET TIME (SE TI)This command, followed by the time (HHMMSS), sets the real time clock time.

Page 39 - 4.1.4.24 SET SNMPv3 (SE V3)

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps34© 2012 Datacom Systems Inc4.1.4.11 SET GATEWAY (SE GA)This command configures the Gat

Page 40

Initial Configuration 35© 2012 Datacom Systems IncExample 2:# SE PO MO 4 FROM 3,2,PortNine#Example 3:# SE PO MO 3 OFF#NOTE: See the 'Exercise - C

Page 41 - Initial Configuration 41

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps36© 2012 Datacom Systems Inc4.1.4.17 SET LINK PROTECT (SE LP)This command configures th

Page 42 - 4.4 IP Address Configuration

Initial Configuration 37© 2012 Datacom Systems Inc4.1.4.18 SET TCP PORT (SE TC PO)This command configures the TCP Port (default 2370) parameter. Init

Page 43 - > HyperTerminal

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps38© 2012 Datacom Systems Inc4.1.4.21 SET SSH (SE SH)This command sets the SSH service (

Page 44

Initial Configuration 39© 2012 Datacom Systems Inc4.1.4.24 SET SNMPv3 (SE V3)This command sets the SNMP service (default ENABLED) process. It is enter

Page 45 - Initial Configuration 45

All rights reserved. No parts of this work may be reproduced in any form or by any means - graphic, electronic, ormechanical, including photocopying,

Page 46

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps40© 2012 Datacom Systems Inc4.2 SERIAL Port Configuration (DB9)Use of the SERIAL DB9 po

Page 47 - Initial Configuration 47

Initial Configuration 41© 2012 Datacom Systems Inc4.3.1 HyperTerminalNOTE: HyperTerminal is the preferred terminal emulation program.Any freely availa

Page 48

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps42© 2012 Datacom Systems Inc4.4 IP Address ConfigurationAll SS-1200-S, SS-2200-S and SS

Page 49 - Initial Configuration 49

Initial Configuration 43© 2012 Datacom Systems IncStep 3. Open the HyperTerminalapplication on your PC byselecting START > All Programs >Accesso

Page 50

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps44© 2012 Datacom Systems IncStep 6. Next, configure the COM Properties. The initial cor

Page 51 - Initial Configuration 51

Initial Configuration 45© 2012 Datacom Systems IncStep 10. SET GATEWAY (SE GA) (if needed) by typing se ga xxx.xxx.xxx.xxx correspondingto your networ

Page 52

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps46© 2012 Datacom Systems IncStep 13. Type exit to save the network address changes and

Page 53 - Initial Configuration 53

Initial Configuration 47© 2012 Datacom Systems IncStep 4. Right click Local Area Connection and from drop down menu select Properties. HighlightIntern

Page 54

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps48© 2012 Datacom Systems IncStep 6. In the Command Prompt window, at the prompt, enter

Page 55 - Initial Configuration 55

Initial Configuration 49© 2012 Datacom Systems IncStep 12. SHOW (SH) by typing sh and press the Enter key to display and affirm that the pendingIP Add

Page 56

5Contents© 2012 Datacom Systems IncTable of ContentsSection 1Terms of Use9...

Page 57 - 4.7 SNMP Configuration

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps50© 2012 Datacom Systems Inc4.5 Exercise - CLI Setting PortsPREMISE: The configurable S

Page 58 -

Initial Configuration 51© 2012 Datacom Systems IncCONFIGURATION: For the connections to be properly set, use the syntax below in the CommandLine Inter

Page 59 - Initial Configuration 59

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps52© 2012 Datacom Systems IncThe default configuration has Ports 1 and 2 hard-wired as a

Page 60

Initial Configuration 53© 2012 Datacom Systems IncPort 7 is set as output for Port 1’s input/output which is set with this syntax:# SET PORT MONITOR 7

Page 61 - 5 Hardware Installation

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps54© 2012 Datacom Systems Inc4.6.1 TELNETNote: For security, TELNET can be disabled usin

Page 62

Initial Configuration 55© 2012 Datacom Systems Inc4.6.2 SSHSecure Shell (SSH ) is a network protocol that uses public key cryptography that allows sec

Page 63 - 5.3 Any-to-Any Connection

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps56© 2012 Datacom Systems IncStep 2. In the Host Name (or IP address) box, enter the hos

Page 64 - 5.4 Management Connection

Initial Configuration 57© 2012 Datacom Systems IncWhether or not to trust the host key is your choice. Connecting within a company network, youmight f

Page 65 - 6 Functional Drawing

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps58© 2012 Datacom Systems Inc4.8 Small Form-Factor Plug ModuleThis section provides info

Page 66 - SS-1204SX-BT-S

Initial Configuration 59© 2012 Datacom Systems Inc4.8.3 Installing the SFP ModuleSFP modules might ship already installed in your SS-1200-S, SS-2200,

Page 67 - 6.2 SS-2200-S Series

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps6© 2012 Datacom Systems Inc...

Page 69 - 7 Application

Hardware Installation 61© 2012 Datacom Systems Inc5 Hardware InstallationThis section describes the SS-1200-S, SS-2200-S and SS-4200-S series hardware

Page 70

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps62© 2012 Datacom Systems IncTAP (SS-1200BT-S series port 1 and port 2) or TAP 1 and TAP

Page 71 - Application 71

Hardware Installation 63© 2012 Datacom Systems Inc5.2 PowerThis section describes the power connection at the network installation site of the SS-1200

Page 72

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps64© 2012 Datacom Systems IncThese port sockets have integrated LEDs that display line s

Page 73 - Application 73

Functional Drawing 65© 2012 Datacom Systems Inc6 Functional DrawingThis section contains the SS-1200-S, SS-2200-S and SS-4200-S series functional draw

Page 74

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps66© 2012 Datacom Systems IncSS-1204LX-SFP-SSS-1204SX-BT-S

Page 75 - 7.2 SS-2200 Series

Functional Drawing 67© 2012 Datacom Systems Inc6.2 SS-2200-S SeriesSS-2206BT-BT-SSS-2206SX-SFP-SSS-2210BT-BT/SFP-S

Page 76

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps68© 2012 Datacom Systems Inc6.3 SS-4200-S SeriesSS-4210BT-SFP

Page 77 - Application 77

Application 69© 2012 Datacom Systems Inc7 ApplicationThis section will present techniques and applications describing the practical use and new remedi

Page 78

7Contents© 2012 Datacom Systems IncSection 5Hardware Installation61...

Page 79 - 8 Customer Service

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps70© 2012 Datacom Systems Incdefault LINK PROTECT settings. With the factory default LI

Page 80

Application 71© 2012 Datacom Systems IncThe factory default for all Any-to-Any ports on all aggregation taps (SS-1200-S series andSS-2200-S series) ar

Page 81

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps72© 2012 Datacom Systems Inc7.1.2 Utilization greater than 50 percent (Telnet configura

Page 82

Application 73© 2012 Datacom Systems IncSOLUTION: The SS-1204BT-BT-S taps the link, accepts the input from the workgroup switch andserver switch, rep

Page 83

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps74© 2012 Datacom Systems IncThe factory default for all aggregation taps (SS-1200-S ser

Page 84

Application 75© 2012 Datacom Systems Inc7.2 SS-2200 SeriesThis section describes an application example to familiarize you with the basic SS-2200-S se

Page 85

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps76© 2012 Datacom Systems IncSOLUTION: The SS-2210BT-BT/SFP-S taps both links, aggregat

Page 86

Application 77© 2012 Datacom Systems IncNow you can begin setting the ports as to which port inputs the data and which ports aggregate and/or output t

Page 88

Customer Service 79© 2012 Datacom Systems Inc8 Customer ServiceThis USERguide was written to help you get to know your new VS-1200 Series quickly and

Page 91

Appendix A - Agent Capabilities MIB 81© 2012 Datacom Systems Inc9 Appendix A - Agent Capabilities MIBThe Datacom Agent Capabilities MIB This Appendi

Page 92

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps82© 2012 Datacom Systems Inc SNMP agents and a set of agent capabilities used to conv

Page 93

Appendix A - Agent Capabilities MIB 83© 2012 Datacom Systems Inc sysObjectID.0 = agentIdCopperConfigurables218 sysObjectID.0 = agent

Page 94

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps84© 2012 Datacom Systems Inc CONTACT-INFO "Datacom Systems Inc

Page 95

Appendix A - Agent Capabilities MIB 85© 2012 Datacom Systems Inc STATUS current DESCRIPTION "The Datacom SNMP agent id

Page 96

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps86© 2012 Datacom Systems Inc } SUPPORTS SNMP-USER-BASED-SM-MIB

Page 97

Appendix A - Agent Capabilities MIB 87© 2012 Datacom Systems Inc ifAdminStatus ifOperStatus --

Page 98

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps88© 2012 Datacom Systems Inc8. References8.1 Normative References [RFC2119] Bradner,

Page 99

Appendix B - Power Supply MIB 89© 2012 Datacom Systems Inc10 Appendix B - Power Supply MIBThe Datacom Power Supply (PS) MIBThis Appendix specifies a p

Page 100 - © 2012 Datacom Systems Inc

Terms of Use 9© 2012 Datacom Systems Inc1 Terms of UseThe following terms and conditions relate to the use of this document. Please note that DatacomS

Page 101

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps90© 2012 Datacom Systems Inc1. IntroductionThis memo defines managed objects and notifi

Page 102

Appendix B - Power Supply MIB 91© 2012 Datacom Systems Inc4.1.1.1 Unsigned32There is one object defined in this MIB module using the SMIv2 Unsigned3

Page 103

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps92© 2012 Datacom Systems IncThe SNMP managed objects using a TimeStamp TC follow:in the

Page 104

Appendix B - Power Supply MIB 93© 2012 Datacom Systems Inc4.4.1 The dcomPowerSupplyStatusTableThis table contains object definitions providing essenti

Page 105

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps94© 2012 Datacom Systems Incpower supply currently in the 'down' state.- when

Page 106

Appendix B - Power Supply MIB 95© 2012 Datacom Systems Inc power supplies associated with Datacom products. Copyright (C)

Page 107

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps96© 2012 Datacom Systems Inc -- assignments under dcomPowerSupplyEvents -- dcomPo

Page 108

Appendix B - Power Supply MIB 97© 2012 Datacom Systems Inc MAX-ACCESS not-accessible STATUS current DESCRIPTION "

Page 109 - 12 Appendix D - FLASHutils

SS-1200-S, SS-2200-S and SS-4200-S Series Link Aggregating Taps98© 2012 Datacom Systems Inc STATUS current DESCRIPTION &quo

Page 110

Appendix B - Power Supply MIB 99© 2012 Datacom Systems Inc -- -- conformance and compliance statements -- dcomPowerSupplyCompliance MODULE-COM

Commentaires sur ces manuels

Pas de commentaire