–8–
Security Codes
• One installer code for entire system (user 1)
• One Master code for entire system (user 2)
• 12 secondary user codes (users 3–14)
• One baby-sitter code (user 15)
• One duress code (user 16)
Baby-sitter Code: A special code that can only be used to disarm the system if
that particular code (or the installer code) was used to arm it.
Duress Code: An emergency code which, when entered by
any
user to disarm
or arm the system, will send a silent duress message to the central station.
Keypad Panic Keys
•Up to 3 programmable panic key functions are provided.
•Designated as Zones 95, 96, 99
•Activated by wired & wireless keypads
• Distinguished by subscriber ID number
Zone Monitor Feature
• The control will sense a high resistance in the loops on hard-wired
zones 2–8 if it is present, and will display a trouble message (rather
than an alarm) for the affected zone when the system is in the disarmed
mode. This feature also prevents the system from being armed while
this high resistance condition exists.
Exit Error False Alarm Prevention Feature
• Enables the system to determine the difference between an actual
alarm and an alarm caused by leaving an Entry/Exit or Interior zone
open after the exit delay expires. If not disarmed in time, an alarm will
sound and an “Exit Error” report sent to the central station.
• An Exit Alarm condition will also occur if an Entry/Exit or Interior zone
re-opens within 2 minutes after the end of an exit delay.
Optional Output Relays and Powerline Carrier Devices (X-10 type)
• Up to 4 relays using one 4204 Relay Module
• Up to 2 relays using one 4229 Zone/Relay Module
• Up to 8 Powerline Carrier devices (you must subtract the number of
relay outputs actually used by the 4204 or 4229 modules, if used)
• Actions programmable to respond to zone activity or manual keypad
entries
Powerline Carrier devices require the use of optional 4300 transformer module
instead of the supplied 1321 AC transformer.
Optional Phone Module
• Supports the Ademco 4285/4286 Phone Module
• Provides access to the system via on premises or off-premises phones
for arming, disarming, etc., plus control of relay outputs and Powerline
Carrier devices.
Paging Feature
• If programmed, the paging feature permits up to 16-digits to be sent to
a pager for user-determined messaging, followed by a system
generated 7-digit condition code which indicates the type of condition
that has occurred and the user number or zone number of occurrence.
Audio Alarm Verification Option
• Provides a programmable Audio Alarm Verification (AAV) option which
can be used in conjunction with an output relay to permit voice dialog
between an operator at the central station and a person at the premises.
• Requires the use of optional AAV unit, such as Eagle model 1241.
U
L
The AAV option may not be used in UL installations.