Si5040
Rev. 1.3 57
Reset settings = 0110 0000
Reset settings = 0001 0001
Register 18. RxdLosClearThresh
BitD7D6D5D4D3D2D1D0
Name RxdLosClearThresh[7:0]
Type R/W
Bit Name Function
7:0 RxdLosClearThresh[7:0] Receiver Digital Loss of Signal Clear Threshold.
Clear threshold that releases a digital LOS event.
The number of consecutive 1024 bit fields with at least one transition that are
required to clear dLos is calculated as RxdLos clearthresh x 16 + 1. See
Figure 11 on page 21.
Register 20. sliceConfig
BitD7D6D5D4D3D2D1D0
Name Reserved sliceEn[2:0]
Type R/W
R
R/W
Bit Name Function
7:4 Reserved Do not change; must only write 0001 to these bits.
3 Reserved
Read returns zero.
2:0 sliceEn[2:0] Slice Mode Enable.
000 = Slice disabled.
001 = Autoslice enabled.
010 = Constant duty cycle slice enabled.
011 = Proportional slice enabled.
100 = Absolute slice mode enabled.