209351 REV B ECO 17314 08/27/2013 Redundant System Controllers RCP2-1100/RCP2-1200 FPRC-1100/FPRC-1200 Operations Manual Teledyne Paradise Datacom L
10 209351 REV B Operations Manual, Redundant System Controllers Optional Equipment includes: • Rack Slides • 100 ft. (30 m ) Control Cable • Swit
100 209351 REV B Operations Manual, Redundant System Controllers 7.6.4 SNMP interface 7.6.4.1 Introduction SNMP-based management was initially tar
Operations Manual, Redundant System Controllers 209351 REV B 101 7.6.4.2 SNMP MIB tree --paradiseDatacom(1.3.6.1.4.1.20712) | +--deviceINFO(1)
102 209351 REV B Operations Manual, Redundant System Controllers settingIndex/settingValue settingTextValue Value OID Description 1/INTEGER SysMo
Operations Manual, Redundant System Controllers 209351 REV B 103 Table 7-11: Detailed Settings (continued from previous page) settingIndex/ setting
104 209351 REV B Operations Manual, Redundant System Controllers Table 7-13: Detailed Conditions conditionIndex/ conditionValue conditionTextValue
Operations Manual, Redundant System Controllers 209351 REV B 105 7.6.4.3 Description of MIB entities deviceINFO This field includes general devic
106 209351 REV B Operations Manual, Redundant System Controllers settings Table contents current device configuration and provides device managemen
Operations Manual, Redundant System Controllers 209351 REV B 107 7.6.4.5 Connecting to a MIB browser For a MIB browser application example, we will
108 209351 REV B Operations Manual, Redundant System Controllers THIS PAGE LEFT INTENTIONALLY BLANK
Operations Manual, Redundant System Controllers 209351 REV B 109 Section 8: Maintenance Switch Controller 8.0 Introduction Teledyne Paradise Datac
Operations Manual, Redundant System Controllers 209351 REV B 11 1.4 Safety Considerations Potential safety hazards exist unless proper precautions
110 209351 REV B Operations Manual, Redundant System Controllers 8.2 Application of a Maintenance Switch Controller Figure 8-3 shows a typical sche
Operations Manual, Redundant System Controllers 209351 REV B 111 This section describes the procedure for setting up the Ethernet IP interface throu
112 209351 REV B Operations Manual, Redundant System Controllers 2.4 After optional reboot, open the Command Prompt console window and enter: C:\&g
Operations Manual, Redundant System Controllers 209351 REV B 113 4. On the RCP unit front panel select sequentially: Main Menu → 2.Com.Setup → 4
114 209351 REV B Operations Manual, Redundant System Controllers THIS PAGE LEFT INTENTIONALLY BLANK
Operations Manual, Redundant System Controllers 209351 REV B 115 This section briefly describes the basic theory related to the physical layer of 10
116 209351 REV B Operations Manual, Redundant System Controllers The main concern is the transient magnetic fields which surrounds the wires and the
Operations Manual, Redundant System Controllers 209351 REV B 117 There are only two unique cable ends in the preceding diagrams, they correspond to
118 209351 REV B Operations Manual, Redundant System Controllers Again, the wires with colored backgrounds may have white stripes and may be
Operations Manual, Redundant System Controllers 209351 REV B 119 C.1 Adding a New RCP Unit to the Universal M&C To add a new unit, choose &quo
12 209351 REV B Operations Manual, Redundant System Controllers 1.4.3 Electrical Discharge Hazards A spark can not only create ESD reliability prob
120 209351 REV B Operations Manual, Redundant System Controllers Choose a log file location by clicking the Browse... button. The default is the &qu
Operations Manual, Redundant System Controllers 209351 REV B 121 If the Amplifier Local Port is changed the RCP unit must be reset. The Gateway Add
122 209351 REV B Operations Manual, Redundant System Controllers THIS PAGE LEFT INTENTIONALLY BLANK
Operations Manual, Redundant System Controllers 209351 REV B 123 Version Feature description 1.20 Dual 1:1 mode introduced (RCPD-1100 controller)
124 209351 REV B Operations Manual, Redundant System Controllers THIS PAGE LEFT INTENTIONALLY BLANK
Operations Manual, Redundant System Controllers 209351 REV B 125 The following pages consist of the Redundant System Controller menu structure and s
126 209351 REV B Operations Manual, Redundant System Controllers THIS PAGE LEFT INTENTIONALLY BLANK
Operations Manual, Redundant System Controllers 209351 REV B 13 2.0 Introduction This section provides information for the initial inspection, inst
14 209351 REV B Operations Manual, Redundant System Controllers 2.4.1 Control Cable Connector (J3) - MS3112E16-23S The primary connection between
Operations Manual, Redundant System Controllers 209351 REV B 15 2.4.3 Serial Port, Local (J5) - DB9 (M) The local serial port is used to support sp
16 209351 REV B Operations Manual, Redundant System Controllers Table 2-4: Parallel I/O Signals Identification Signal Pin Function Notes Amp 1 A
Operations Manual, Redundant System Controllers 209351 REV B 17 2.4.6 External Alarm Port (J8) - DB9 (F) [IO Board Version 001] An external alarm p
18 209351 REV B Operations Manual, Redundant System Controllers 2.5 Prime Power Connection (J1, J2) Two separate removable power supplies are provi
Operations Manual, Redundant System Controllers 209351 REV B 19 2.6.2 24V Power Supply Module, High Power option Figure 2-4 shows an outline drawin
2 209351 REV B Operations Manual, Redundant System Controllers © 2013 Paradise Datacom LLC Printed in the USA Teledyne Paradise Datacom, a Teledyne
20 209351 REV B Operations Manual, Redundant System Controllers 2.6.3 48V Power Supply Module Figure 2-5 shows an outline drawing of a 48V power su
Operations Manual, Redundant System Controllers 209351 REV B 21 Section 3: Front Panel Overview & Operation 3.0 Introduction The front panel is
22 209351 REV B Operations Manual, Redundant System Controllers 3.0.4 Amplifier Select Keys The Amplifier Select Keys on the mimic display panel a
Operations Manual, Redundant System Controllers 209351 REV B 23 3.0.7 Local / Remote Key The Local / Remote Key selects whether the controller is
24 209351 REV B Operations Manual, Redundant System Controllers 3.1 Local / Remote control Control of the RCP/FPRC can be handled through Front Pan
Operations Manual, Redundant System Controllers 209351 REV B 25 3.3 Local (Front Panel) Menu Structure Figure 3-4 shows the VFD Menu Structure hier
26 209351 REV B Operations Manual, Redundant System Controllers 3.3.1 Sys Info This is the informative sublevel of the menu structure. This menu co
Operations Manual, Redundant System Controllers 209351 REV B 27 3.3.1.1 Sys Info - Page 1 This page is the system information page of the Sys Info
28 209351 REV B Operations Manual, Redundant System Controllers SysAddr sets the controller unique network address. The address range is 1 to 255.
Operations Manual, Redundant System Controllers 209351 REV B 29 3.3.1.4 Sys Info - Page 4 This page pertains to the advanced system diagnostic fe
Operations Manual, Redundant System Controllers 209351 REV B 3 Table of Contents ...
30 209351 REV B Operations Manual, Redundant System Controllers Major SSPA faults are represented as HPAXXX, where “X” could be “1” or “0” depending
Operations Manual, Redundant System Controllers 209351 REV B 31 3.3.1.7 SSPA Subsystem Information - Pages 1-5 Page 1 (RCP firmware version 3.10
32 209351 REV B Operations Manual, Redundant System Controllers 3.3.1.10 IP Info - Page 3 This page shows RCP settings related to the IP interface
Operations Manual, Redundant System Controllers 209351 REV B 33 3.3.2 Serial Communication Parameters This section describes the serial communicati
34 209351 REV B Operations Manual, Redundant System Controllers 3.3.2.3 Sys. Address Sets the network address of the controller if used in a RS485
Operations Manual, Redundant System Controllers 209351 REV B 35 3.3.3.3 Control Selects between Local and Remote mode. Note that this is the same
36 209351 REV B Operations Manual, Redundant System Controllers 3.3.4.1 MjrFaults Allows user to assign priority and select those inputs that con
Operations Manual, Redundant System Controllers 209351 REV B 37 3.3.5 Options Menu This section describes the features available on the Options men
38 209351 REV B Operations Manual, Redundant System Controllers 3.3.5.5 Reset Forces a reset of the controller’s internal microcontroller. 3.3.5
Operations Manual, Redundant System Controllers 209351 REV B 39 3.3.6 Calibration Menu When the controller is set up to perform LNA/LNB Fault Track
4 209351 REV B Operations Manual, Redundant System Controllers 3.2.2 Auto Mode ...
40 209351 REV B Operations Manual, Redundant System Controllers 3.3.6.3 Calibrate Allows the user to calibrate the system LNAs. 3.3.6.4 View LN
Operations Manual, Redundant System Controllers 209351 REV B 41 Section 4: System Setup & Control with RCP 4.0 Introduction This section descri
42 209351 REV B Operations Manual, Redundant System Controllers 4.1.1 LNA / LNB 1:1 Redundant System Operation This section covers the operation o
Operations Manual, Redundant System Controllers 209351 REV B 43 4.1.1.1 LNA/LNB Fault Tracking To set up the RCP2-1100 for LNA/LNB fault tracking
44 209351 REV B Operations Manual, Redundant System Controllers 4.1.2 SSPA 1:1 Redundant System Operation The RCP2-1100 can be configured to accept
Operations Manual, Redundant System Controllers 209351 REV B 45 4.2 Operation of 1:2 System with RCP2-1200 Figure 4-5 shows the basic block diagram
46 209351 REV B Operations Manual, Redundant System Controllers The LNAs or LNBs are powered by the RCP2-1200 Controller via the control cable. Two
Operations Manual, Redundant System Controllers 209351 REV B 47 4.2.1.1 LNA/LNB Fault Tracking To set up the RCP2-1200 for LNA/LNB fault tracking
48 209351 REV B Operations Manual, Redundant System Controllers 4.2.2 SSPA 1:2 Redundant System Operation The RCP2-1200 can be configured to accept
Operations Manual, Redundant System Controllers 209351 REV B 49 4.3 Operation of 1:1 Fixed Phase Combined System with FPRC-1100 The 1:1 Fixed Phase
Operations Manual, Redundant System Controllers 209351 REV B 5 Section 4: System Setup & Control with RCP ...
50 209351 REV B Operations Manual, Redundant System Controllers 4.4 Operation of 1:2 Fixed Phase Combined System with FPRC-1200 The 1:2 Fixed Phase
Operations Manual, Redundant System Controllers 209351 REV B 51 4.5 RCP Remote Control of System SSPAs RCP units that meet certain conditions are c
52 209351 REV B Operations Manual, Redundant System Controllers 4.5.1 Configuring the RCP for Remote Control Mode The RCP unit has to be configured
Operations Manual, Redundant System Controllers 209351 REV B 53 RCP2 J5 Serial Local SSPA1 Serial Main J4 SSPA2 Serial Main J4 SSPA3 Serial Main J4
54 209351 REV B Operations Manual, Redundant System Controllers All attached units must be properly configured in order to work under RCP Remote Con
Operations Manual, Redundant System Controllers 209351 REV B 55 4.5.2.2 Change Attenuation Level To change the overall attenuation level of a contr
56 209351 REV B Operations Manual, Redundant System Controllers 4.5.2.4 Units This option allows the user to select the RF Power measurement units
Operations Manual, Redundant System Controllers 209351 REV B 57 Important! Real system output power most likely will be different from this paramete
58 209351 REV B Operations Manual, Redundant System Controllers 4.7 Advanced system level troubleshooting with RCP The RCP controller offers the ab
Operations Manual, Redundant System Controllers 209351 REV B 59 5.0 Design Philosophy The RCP series of redundant controllers was designed to achie
6 209351 REV B Operations Manual, Redundant System Controllers Section 7: Remote Control Interface ...
60 209351 REV B Operations Manual, Redundant System Controllers 5.0.2 Digital Core Board The digital core board is the heart of the redundant contr
Operations Manual, Redundant System Controllers 209351 REV B 61 5.0.3 I/O Board Assembly The I/O Board Assembly contains the primary parallel (hard
62 209351 REV B Operations Manual, Redundant System Controllers 5.0.5 Front Panel Mimic Display The front panel display is a densely integrated arr
Operations Manual, Redundant System Controllers 209351 REV B 63 Paradise Datacom control cables utilize 20 conductors of #18 AWG stranded wire. The
64 209351 REV B Operations Manual, Redundant System Controllers THIS PAGE LEFT INTENTIONALLY BLANK
Operations Manual, Redundant System Controllers 209351 REV B 65 6.0 Introduction The RCP series of redundant controllers has been designed to be ma
66 209351 REV B Operations Manual, Redundant System Controllers 6.2 Firmware Programming The internal firmware is field programmable in the RCP red
Operations Manual, Redundant System Controllers 209351 REV B 67 Step 5: After all connections have been made and all zip files unpacked, locate the
68 209351 REV B Operations Manual, Redundant System Controllers 6.3 Restoring Factory Pre-set Settings on RCP2/FPRC The Teledyne Paradise Datacom R
Operations Manual, Redundant System Controllers 209351 REV B 69 Skip the following steps if the controller is not configured as a primary power sour
Operations Manual, Redundant System Controllers 209351 REV B 7 Appendix A: Ethernet Interface Quick Set-Up ...
70 209351 REV B Operations Manual, Redundant System Controllers 6.4.2 Installing a New Power Supply Module First, ensure that the new power supply
Operations Manual, Redundant System Controllers 209351 REV B 71 7.0 Overview A system, which includes a RCP2, can be managed from a remote computer
72 209351 REV B Operations Manual, Redundant System Controllers The SSPA subsystem units can also be accessed directly through a packet wrapping tec
Operations Manual, Redundant System Controllers 209351 REV B 73 7.1.2 Control Inputs The parallel control inputs are opto-isolated inputs with pul
74 209351 REV B Operations Manual, Redundant System Controllers 7.2 Serial Communication This section describes the normal communication protocol b
Operations Manual, Redundant System Controllers 209351 REV B 75 7.2.1.3 Source Address The source address specifies the address of the node that is
76 209351 REV B Operations Manual, Redundant System Controllers The Response frame from the receiver will contain a Get Response designator in the C
Operations Manual, Redundant System Controllers 209351 REV B 77 7.2.2.5 Data Address / Error Status / Local Port Frame Length This field is a tag
78 209351 REV B Operations Manual, Redundant System Controllers In case of Packet Wrapper request frame (Tag 6), data address field used to specify
Operations Manual, Redundant System Controllers 209351 REV B 79 7.2.3 Trailer Packet The trailer component contains only one byte called the Frame
8 209351 REV B Operations Manual, Redundant System Controllers Figure 7-13: Terminal Mode Example ...
80 209351 REV B Operations Manual, Redundant System Controllers 7.2.4 Timing issues There is no maximum specification on the inter-character spacin
Operations Manual, Redundant System Controllers 209351 REV B 81 7.3 Access optional SSPA subsystem with Packet Wrapper technique Features introduce
82 209351 REV B Operations Manual, Redundant System Controllers Byte Tag Description 1 0xAA Frame Sync 1 2 0x55 Frame Sync 2 3 Destination Ad
Operations Manual, Redundant System Controllers 209351 REV B 83 Table 7-6: System Settings Data Values Data Address # Bytes Description Limits an
84 209351 REV B Operations Manual, Redundant System Controllers Data Address # Bytes Description Limits and valid values 1 1 Unit 1 Fault state
Operations Manual, Redundant System Controllers 209351 REV B 85 Data Address # Bytes Description Limits and valid values 1 2 LNA unit 1 c
86 209351 REV B Operations Manual, Redundant System Controllers 7.4 Examples This section contains several examples of serial data exchange between
Operations Manual, Redundant System Controllers 209351 REV B 87 The RCP2-1200 replies with the following response string. Byte Position Byte Value
88 209351 REV B Operations Manual, Redundant System Controllers 7.4.2 Example 2 The host computer requests the RCP2-1200 system thresholds. The PC
Operations Manual, Redundant System Controllers 209351 REV B 89 7.4.3 Example 3 The host computer requests the RCP2-1200 network address. The PC r
Operations Manual, Redundant System Controllers 209351 REV B 9 Section 1: General Information 1.0 Introduction This section provides the general i
90 209351 REV B Operations Manual, Redundant System Controllers 7.4.4 Example 4 The host computer requests the Priority be set to Polarity #2. The
Operations Manual, Redundant System Controllers 209351 REV B 91 7.5 Terminal Mode Serial Protocol The Teledyne Paradise Datacom RCP Redundant Syste
92 209351 REV B Operations Manual, Redundant System Controllers The following procedure will guide the user through the remote terminal setup, using
Operations Manual, Redundant System Controllers 209351 REV B 93 • In the next window, select the following as shown in Figure 7-11: Bits per Seco
94 209351 REV B Operations Manual, Redundant System Controllers • Your PC is now configured to work with the RCP in Terminal mode. To establish
Operations Manual, Redundant System Controllers 209351 REV B 95 7.6 Ethernet Interface 7.6.1 Overview The RCP2 Ethernet port (J9) supports several
96 209351 REV B Operations Manual, Redundant System Controllers UDP (User Datagram Protocol) was chosen over TCP (Transmission Control Protocol) bec
Operations Manual, Redundant System Controllers 209351 REV B 97 specific address of the remote host will lock RCP2 access to this host. Packets rece
98 209351 REV B Operations Manual, Redundant System Controllers selected as the primary interface, you should be able to verify the network connecti
Operations Manual, Redundant System Controllers 209351 REV B 99 The integrated web server loads a web page and a Java Applet. The activity indicator